- Home
- Cryogenic Testing
- Cryogenic Testing
Cryogenic Testing
How a valve is proved at −196 °C, and why the test report is more informative than the nameplate.
Cryogenic testing immerses the valve in liquid nitrogen and measures seat leakage and operability at temperature. The pass criteria depend on the specification, and the differences between specifications are large enough to matter commercially.
What the test actually proves is that the extended bonnet keeps the packing above 0 °C, that the trim still operates after cold shrinkage, and that the seat material retains enough resilience to seal. Any one of those three can fail on a valve that looks correct on a drawing.
We test to the project specification and issue the report with the actual leakage figures rather than a pass mark only.
Send the piping class, not the part number
We check the dimensions, the material and the standard before we price — which is the part that decides whether the valve actually fits. RFQ answered within one working day.